|本期目录/Table of Contents|

[1]柴建源,马景辉,冉科呈,等.基于反应系数法的内嵌加肋管混凝土辐射地板等效热阻传热模型[J].浙江理工大学学报,2025,53-54(自科一):80-87.
 CHAI Jianyuan,MA Jinghui,RAN Kecheng,et al.An equivalent thermal resistance heat transfer model for concrete radiant floors with embedded ribbed tubes based  on the reaction coefficient method[J].Journal of Zhejiang Sci-Tech University,2025,53-54(自科一):80-87.
点击复制

基于反应系数法的内嵌加肋管混凝土辐射地板等效热阻传热模型()
分享到:

浙江理工大学学报[ISSN:1673-3851/CN:33-1338/TS]

卷:
第53-54卷
期数:
2025年自科第一期
页码:
80-87
栏目:
出版日期:
2025-01-10

文章信息/Info

Title:
An equivalent thermal resistance heat transfer model for concrete radiant floors with embedded ribbed tubes based  on the reaction coefficient method
文章编号:
1673-3851 (2025) 01-0080-08
作者:
柴建源马景辉冉科呈李兴宇陶盛
浙江理工大学建筑工程学院,杭州 310018
Author(s):
CHAI Jianyuan MA Jinghui RAN Kecheng LI Xingyu TAO Sheng
School of Civil Engineering and Architecture, Zhejiang Sci-Tech University, Hangzhou 310018, China
关键词:
内嵌加肋管混凝土辐射地板热性能反应系数法等效热阻传热模型
分类号:
TU111-48
文献标志码:
A
摘要:
为探究内嵌加肋管混凝土辐射地板在间歇运行工况下的热响应特性,根据其传热过程,采用反应系数法建立了内嵌加肋管混凝土辐射地板等效热阻传热模型,并通过模型的模拟值与实验值对比验证等效热阻传热模型的准确性。实验结果表明:利用无肋圆管等效内嵌加肋管混凝土辐射地板内部传热时,当温度离散间隔取05 h,上表面温度、核心层温度模拟值与实验值的相对误差均小于4%;蓄释热能力模拟值与实验值的相对误差均小于10%。该内嵌加肋管等效热阻传热模型具有较高的精度,能较好地再现内嵌加肋管混凝土辐射地板的动态传热过程。该研究通过反应系数法,用线性方程组对内嵌加肋管混凝土辐射地板的复杂传热过程进行描述,计算快捷,有助于内嵌加肋管混凝土辐射地板在工程上的应用推广。

参考文献/References:

[1]梁浩宇,贾捷,周轩,等. 用于热泵采暖的强制对流散热器多参数耦合优化[J]. 太阳能学报,2023,44(10):107-112.
[2]Xu Y, Sun B B, Liu L J, et al. The numerical simulation of radiant floor cooling and heating system with double phase change energy storage and the thermal performance[J]. Journal of Energy Storage, 2021, 40: 102635.
[3]范鹏,马立. 复合相变墙体供暖特性数值模拟研究[J]. 区域供热,2023(4):25-31.
[4]刘洁,杨英英,李爱征,等. 用于地板辐射采暖的多元水合盐复合相变砂浆的制备及性能研究[J]. 储能科学与技术,2023,12(12):3655-3662.
[5]张春枝,周思童,李涛,等. 相变材料填充结构对地板辐射供暖热性能的影响研究[J]. 新型建筑材料,2021,48(11):93-98.
[6]Sun W C, Zhang Y X, Ling Z Y, et al. Experimental investigation on the thermal performance of double-layer PCM radiant floor system containing two types of inorganic composite PCMs[J]. Energy and Buildings, 2020, 211: 109806.
[7]成鑫磊,穆锐,孙涛,等. 固液相变材料的封装制备及在建筑领域的研究进展[J]. 材料导报,2024,38(5):73-87.
[8]Oravec J, ikula O, Krajcˇík M, et al. A comparative study on the applicability of six radiant floor, wall, and ceiling heating systems based on thermal performance analysis[J]. Journal of Building Engineering, 2021, 36: 102133.
[9]杨艺真. 混凝土辐射地板蓄热强化及热工性能研究[D]. 杭州: 浙江理工大学, 2021: 31-40.
[10]Jin X, Yang J C, Li M, et al. Experimental and numerical study on the thermal energy storage performance of a novel phase-change material for radiant floor heating systems[J]. Building and Environment, 2022, 223: 109491.

相似文献/References:

[1]杨艺真,马景辉,戴博斌,等.冷热工况下混凝土辐射地板的蓄释热性能分析[J].浙江理工大学学报,2021,45-46(自科一):117.
 YANG Yizhen,MA Jinghui,DAI Bobin,et al.Thermal storage and release characteristics of concrete radiant floor under cooling and heating conditions[J].Journal of Zhejiang Sci-Tech University,2021,45-46(自科一):117.

备注/Memo

备注/Memo:
收稿日期: 2024-04-13
网络出版日期: 网络出版日期2024-09-13
基金项目: 国家自然科学基金青年科学基金项目(52206029)
作者简介: 柴建源(1998—),男,河南信阳人,硕士研究生,主要从事辐射冷暖房方面的研究
通信作者: 马景辉,E-mail:mzh58@hotmail.com
更新日期/Last Update: 2025-01-07